Contact us for your exact requirements and will work together to fullfill it !!

Avant Enviro
  • Sign In
  • Create Account

  • My Account
  • Signed in as:

  • filler@godaddy.com


  • My Account
  • Sign out

  • Home
  • Products
    • Viz Solo
    • Viz Duo
    • Viz Multi
    • COD/BOD/TSS/TOC Sensor
    • VizSens Ph Sensor Analog
    • VizSens PH Sensor Digital
    • VizSens Orp Sensor Analog
    • AnalogConductivitySensor
    • DigitalConductivitySensor
    • Dissolved Oxy Sensor
    • Chlorine Dioxide Sensor
    • Suspended Waste Sensor
    • Turbidity Sensor
    • TurbiditySensor-Low Range
    • Chlorophyll Sensor
    • Blue-Green Algae Sensor
    • Oil in Water Sensor
    • Ammonia Nitrogen Sensor
    • Nitrate Nitrogen Sensor
  • Careers
  • Quotation Generate
  • More
    • Home
    • Products
      • Viz Solo
      • Viz Duo
      • Viz Multi
      • COD/BOD/TSS/TOC Sensor
      • VizSens Ph Sensor Analog
      • VizSens PH Sensor Digital
      • VizSens Orp Sensor Analog
      • AnalogConductivitySensor
      • DigitalConductivitySensor
      • Dissolved Oxy Sensor
      • Chlorine Dioxide Sensor
      • Suspended Waste Sensor
      • Turbidity Sensor
      • TurbiditySensor-Low Range
      • Chlorophyll Sensor
      • Blue-Green Algae Sensor
      • Oil in Water Sensor
      • Ammonia Nitrogen Sensor
      • Nitrate Nitrogen Sensor
    • Careers
    • Quotation Generate
Avant Enviro

Signed in as:

filler@godaddy.com

  • Home
  • Products
    • Viz Solo
    • Viz Duo
    • Viz Multi
    • COD/BOD/TSS/TOC Sensor
    • VizSens Ph Sensor Analog
    • VizSens PH Sensor Digital
    • VizSens Orp Sensor Analog
    • AnalogConductivitySensor
    • DigitalConductivitySensor
    • Dissolved Oxy Sensor
    • Chlorine Dioxide Sensor
    • Suspended Waste Sensor
    • Turbidity Sensor
    • TurbiditySensor-Low Range
    • Chlorophyll Sensor
    • Blue-Green Algae Sensor
    • Oil in Water Sensor
    • Ammonia Nitrogen Sensor
    • Nitrate Nitrogen Sensor
  • Careers
  • Quotation Generate

Account


  • My Account
  • Sign out


  • Sign In
  • My Account

VizSens-RCL Residual Chlorine/Chlorine Dioxide Sensor

Reliable Measurement for Water Disinfection

 The VizSens-RCL is a leading-edge residual chlorine/chlorine dioxide sensor designed for dependable measurement of these disinfectants in various water environments. It employs a sophisticated pulse principle for accurate detection, eliminating the need for flow rate and stirring mechanisms that can be cumbersome or impractical in certain applications. 

Key Features of the VizSens-RCL Sensor

 

  • Patented Pulse Principle: Utilizes a unique pulse principle for accurate measurement of residual chlorine or chlorine dioxide. This innovative approach eliminates the requirement for flow rate and stirring mechanisms, simplifying operation and installation.
  • Wide Measurement Range:  Measures a broad range of chlorine and chlorine dioxide concentrations (specific range depends on model variant), making it suitable for diverse disinfection applications.
  • Factory Calibration:  The sensor comes factory-calibrated, ensuring reliable measurements from the outset and minimizing setup time. Calibration is typically required only once a year, with the option for field calibration if needed.
  • Long-Term Stability: Delivers consistent and dependable readings over extended periods, reducing maintenance requirements and ensuring data integrity.
  • Durable Construction: Features a robust design for long-term use in harsh environments, withstanding exposure to chemicals commonly used in water disinfection processes.

Benefits of Using the VizSens-RCL Sensor

 

  • Accurate and Reliable Measurement: Provides dependable data on residual chlorine or chlorine dioxide levels for effective water disinfection.
  • Simplified Operation:  The pulse principle eliminates the need for flow rate and stirring mechanisms, streamlining operation and maintenance.
  • Reduced Maintenance: Factory calibration and long-term stability minimize maintenance requirements and downtime.
  • Versatile Applications: The wide measurement range and durable construction accommodate diverse disinfection applications in various water qualities.

Applications of the VizSens-RCL Sensor

 

The VizSens-RCL sensor's innovative design and user-friendly features make it suitable for a wide range of applications requiring accurate monitoring of residual chlorine/chlorine dioxide levels, including:


  • Water Treatment Plants:  Monitoring chlorine or chlorine dioxide concentration is crucial for ensuring effective disinfection in water treatment plants. The VizSens-RCL's simplified operation and reliable measurement are valuable assets in these critical facilities.
  • Swimming Pools and Spas:  Maintaining proper chlorine levels is essential for safe and hygienic recreational water environments. The VizSens-RCL provides real-time data for effective chlorine disinfection in pools and spas.
  • Food and Beverage Industry:  Chlorine or chlorine dioxide disinfection is often used in food and beverage production to ensure product safety and quality. The VizSens-RCL sensor helps maintain compliance with strict hygiene standards in this industry.
  • Industrial Process Control:  Residual chlorine or chlorine dioxide monitoring is required in various industrial processes where disinfection is necessary. The VizSens-RCL's versatility and wide measurement range make it suitable for diverse industrial applications.


By providing a reliable and easy-to-use solution for residual chlorine/chlorine dioxide measurement, the VizSens-RCL sensor empowers users in various sectors to maintain optimal disinfection levels, ensuring public health, product safety, and environmental protection.

Technical Specifications for VIZSENS-RCL

 Basic Information:

  • Principle: Constant voltage method

Measurement Ranges:

  • Chlorine Measurement Range: 0-2 mg/L, 0-20 mg/L (optional)
  • pH Measurement Range: 5-8 pH

Accuracy and Precision:

  • Measurement Accuracy: ±3% or ±0.3 mg/L, whichever is greater
  • Temperature Compensation: Manual or automatic
  • Repeatability: ±0.3 mg/L

Operating Conditions:

  • Pressure Range: 0.3 Mpa
  • Calibration: 2-Point Calibration
  • Flow Rate: 30-60 L/h
  • Main Material: 316L Stainless steel shell

Physical Specifications:

  • Dimensions: Diameter 13.5mm * Length 178.5mm
  • Weight: 1.4 KG
  • Protective Rate: IP68/NEMA6P
  • Cable Length: Standard: 10m, maximum can be extended to 100m